Cladding Design Considerations

Content & images courtesy of TDCA

Let's go!

Remember to consider movement gaps and, if using T&G boards, think about tongue thickness and widths, which should vary depending on the board’s width as well as the species you are using. For T&G boards, they should be no wider than 125mm unless using Accoya which is classed as a small movement species and available in maximum widths of 195mm.

Moisture and movement

Timber is a natural material which reacts to changes in moisture from the atmosphere. This causes the timber to expand and contract according to humidity. This natural movement should be accommodated within the design.

Timber species are assigned to movement classes, allowing movement to be predicted. For example, the dimensions of pine, oak and spruce will only change by around 1% for every 4% increase in moisture content.

To minimise timber “breathing”, as it is often called, try to aim for around 16% moisture content at the time of installation. The only time this should not be the case is when using unseasoned wood, such as green oak, which will need additional allowances as it will shrink after installation as it dries.

Minimising the Effects of Moisture

Moisture in the air and direct contact with water can affect timber cladding. Luckily, there are ways you can minimise the effects they cause and extend the lifespan of your wood by:

  • Using species which are characterised as more stable with only a little movement
  • Using timber which has been processed for timber cladding use
  • Incorporating overhangs and eaves which will keep rain away from the wood, or flashing where these are not possible
  • Leaving at least 200mm between the ground and your cladding, and use a surface that helps to diffuse water, such as gravel, to prevent water lines and algae
  • Where tongue and groove boards are used, the tongue should be of sufficient length to prevent disengagement when the wood moves
  • Adding a water repellent finish before installation

Moisture and Durability

One of the main challenges to timber’s life service is moisture. If the wood is wet and not allowed to dry, it will attract fungi and with it, eventually, rot. If the moisture content of your cladding is under 20% throughout its use, it is much less likely to decay or experience mould growth. When installing cladding, be sure to take measures against additional uptake of moisture, as well as designing to prevent water retention in the wood.

If you extend the durability of your timber cladding by choosing the right species and good quality finishes if desired, it will perform its function year after year.

Performance of Your Timber

The performance of your cladding is highly affected by how it is designed and fixed, and the materials you choose for your project. Timber species can be classified according to their durability for each particular use class. Cladding (above ground contact) is Use Class 3, so look for timbers that are durable or at least moderately durable in this category.

If you do experience issues with your timber’s performance, it is likely to be due to one of the following:

  • It is not a suitable cladding species
  • The timber becomes excessively wet due to poor installation, design or maintenance

Durability of your timber

The UK’s climate is very temperate, meaning that ensuring your timber is durable must be a vital consideration when designing cladding. You should only use a species that has been specified for external use above ground (use class 3), otherwise you are leaving yourself open to trouble.

In standards, outdoor cladding is categorised as Use Class 3. This Use Class is split into uncoated and coated applications

Of course, climate change is affecting the British climate and this should always be considered in design. Defra notes that any buildings set to stand for over 60 years should be planned for warmer and wetter weather, as well as extreme weather such as storms. The increasing warmth and rain are likely to make decay and insect issues more common. This makes it essential to ensure that your timber cladding is durable for the long term and can be easily maintained.

Wood Protection

Industrial wood protection processes should be used where long-term performance is needed and if the species you are working with is not sufficiently durable. It should also be considered if you have to use sapwood in your structures, which is always less durable. The protection options for timber cladding are:

  • Wood preservatives
  • Wood modification (thermal or chemical)

Protection from fire

Where required by Building Regulations, the performance of timber cladding can be upgraded to achieve a Euroclass B or C standard. Application is highly regulated, so it is wise to check that certification is in place for the profile and species of choice.

If you’re looking for guidance on timber flame retardants, look to the Wood Protection Association (WPA) for help. They publish a manual which details how you can ensure your timber is fit for use. Make sure that the performance achieved in your fire test corresponds to the size and species of cladding you are using.

For more information, we recommend reading the WPA Flame Retardant Specification on the WPA website.

Service life

In BS 8417: Timber Preservation – Code of Practice, you will find the benchmark number for the life of wood used for construction purposes. There are three categories of desired service life: 15, 30 and 60 years. How long you need your timber cladding to last should always be detailed in your specification.
For pressure treated cladding, the default expected length of life is 30 years. If you are using a hardwood that is naturally durable, no treatment is needed and the durability class assigned to the species will determine the likely service life.

Desired service lives are not guarantees but rather an indication of what you can expect. Remember, too, that they assume the cladding will be installed according to good practice guidance, and that the timber is being used as recommended. Other factors, such as mechanical damage or vandalism, won’t be considered in these benchmarks.

Impact on adjacent surfaces

When designing timber cladding, it is not just the timber you need to consider. Using wood on the exterior of your structures can also affect the surfaces around if you are not careful. Some species, for example, can end up leaving stains or watermarks on adjacent materials and can even corrode metals they are in contact with.

Timber is an organic material that contains a wide range of natural chemical compounds which can move freely, known as extractives. These are far more common in heartwood and can even be the cause of the darker colour of this area of timber. Tannins in the wood can leach when the wood becomes wet, leaving surfaces around the area with watermarks. This is particularly the case with Oak, which is famous for staining concrete surfaces nearby.

Flashings, masonry and rendered walls can all be affected by wood staining. These areas can usually be cleaned, luckily, with a household detergent. To avoid corrosion on metals from the acidic tannins in timber, ensure you use the right type of fixing for your species.

Timber cladding images

View a gallery of timber cladding images on the TDCA website here.