When designing cladding, there are a number of key considerations to remember.
Beautiful, long-lasting cladding relies on design details. These are the principles which dictate how your cladding should be installed, from cladding build-up to covering arrangements on masonry and timber frame buildings. Before looking at each principle in more detail, here are some key points you should consider:
- Only use species of timber (and fixings) which are described as being ideal for exterior use
- Unless you are working with green oak or other dense hardwoods, your timber should have a moisture content of 16% with no variation larger than 4%
- Install your timber with movement gaps or overlaps suitable for the species and use to accommodate its natural contraction and expansion
- Timber cladding acts as a rain screen and must include a cavity behind the timber that is ventilated at the top and bottom to allow for drainage and airflow, allowing any water to drain away.
- The depth of the cavity will vary depending on the battens you use, which are usually at least 25mm but can easily be 38mm or over
- Vertical cladding should incorporate counter battens so that there is a continuous cavity behind the timber
- If you are worried about small animals and insects getting into the cavity, use vermin mesh to keep them out
- Battens should match the service life of your cladding boards and should not split when fixings are installed
- Place fixings in your cladding boards at a minimum of 20mm from the ends of the boards and at quarter points
- Pressure-treated timber which is crosscut on-site should be recoated at the ends with an end-grain preservative