Cladding Fixings
Content & images courtesy of TDCA
When installing cladding, fixings are vital to keep the timber securely in place. Understand more about exterior fixing specifications with these instructions:
- Any metal fixings need to be resistant to corrosion
- The most secure method for installing your wood using fixtures is through the face fixing
- Two fixings should be used per board to batten intersections, and they should be applied at quarter points. If your board is narrow, for example less than 100mm, only one fixing may suffice
- Any fixings should be flush with the surface of your wood
- The dimensions of your screws need to be relative to the thickness and stability of your timber boards
- Fixings should be placed 25% in from either side of the board, at a minimum of 20mm from the ends of the timber
- If you are using a dense species that is prone to splitting, pre-drill any pilot holes to 70% shank diameter
- Any timber cladding you use should have a moisture content of 16% when installing it to minimise the effects of movement, with a variation of no more than ± 4%
Should You Use Screws or Nails?
It is common to secure cladding with “face fixed” screws and nails, which attach cladding to the batons behind, going through the front face of the wood. But whether you should use screws or nails depends on the species of timber you are using.
Softwood – Small headed ring shank nails are a great choice when you are using most softwood species for your cladding. Although low-density species, like Western Red Cedar, will require larger heads on the nails to prevent them from being pulled through.
Hardwood – If you are working with hardwoods (or harder softwoods, like Douglas Fir or Siberian Larch), it is recommended that you use screws. Hardwoods are typically very dense and it is more likely they will split when you apply fixings, so pre-drill pilot holes that are 70% of the fixings shank diameter to prevent splitting. On green oak, which is more prone to shrinkage, use a minimum of 4mm oversized holes, and apply washers with larger heads to keep your fixings secure.
Picture shows heat treated Platowood Frake hardwood cladding. Fixing with large headed stainless steel screws into 2mm oversize holes to allow for any movement. Photo: Howarth Timber.
Metal types
Any metal fixings you use, such as screws, nails or bolts, should be resistant to corrosion regardless of whether you will be finishing the surface of your wood with a treatment. Common materials which are good to use include:
- Silicone bronze
- Stainless steel – Austenitic grade
- High performance coated steel
- Hot dipped galvanised copper
Avoid using aluminium, brass or electroplated steel. You also should not mix materials at the same fixing area, as this can increase the chance of corrosion. If you are using hot dipped galvanised materials, you need to avoid damaging the surface with hammers and driver bits as this can cause corrosion of the steel underneath.
It is also vital that you only use stainless steel when working with any timber species which contains a high tannin content or corrosive oils, such as Douglas Fir, Western Red Cedar and some hardwoods such as Oak. If you do not, you may see permanent black spots staining the timber and adjacent surfaces.
Application
If you are using pneumatic fixing guns when applying your screws, nails and bolts, be very careful to avoid affecting the surface with impact damage or driving the fixings below the surface of the timber. A lot of fixings which are supplied for gun application will come with D shaped, off-centre heads which are much better for application.
If you are fixing screws, “impact” handheld screwdrivers are your best bet. These aren’t as likely to cause issues or damage the timber, and they give you more control over how far the screw will be inserted. It will also keep you clear of the coating burn that high-speed drivers can cause.
All your fixings should sit flush with the surface of your timber, being neither countersunk nor punched. To avoid further movement after fixing, ensure the moisture content of your timber is around 16% when installing it.
If you need concealed fixings, your timber can be back fixed to your battens. Or you can install them with a proprietary support system or fastening bracket. These concealed fixings are the best option for the prefabrication of your timber cladding panels.
Cladding fixing positions
The way you fix your cladding is going to vary with different board styles, but there are set principles that work regardless and should always be followed:
- Where abutting boards are installed, use a double batten system with the batten extending the width of one of the boards
- Fixing points on board ends should always be pre-drilled to avoid the timber splitting
- Any boards that are over 100mm in width should have two fixings at every batten crossing
- Ensure your fixings are at least 25% in from either side, with at least 20mm between the fixing and the end of the board
- If you are creating the “board on board” style, install your fixings to the top board but avoid it passing through the second board otherwise opposing movement will place excessive strain on the fixing